Dosing pumpsSingle dosing pump

Versa VX-1 Dosing Pump Single

Versa VX-1 Dosing Pump Single is a Mobius-programmable peristaltic system for dosing and controlled liquid transfer.

EcoTech Marine logoEcoTech MarineVisit website

Overview

Programmable peristaltic pumps with planetary transmission, a stated minimum flow of 6 µl/min, a continuous maximum of 200 ml/min and a volumetric maximum of 300 ml/min, Mobius control, and standalone VX-1 or VXF-1 Four Pack configurations.

Who It Is For

The smart, multi-functional peristaltic dosing pump EcoTech Marine Versa (available as a standalone Versa VX-1 or as the Versa VXF-1 Four Pack, with four VX-1 pumps and a Base Station) is designed for:

  • Marine aquarists seeking programmable dosing from the stated minimum flow of 6 µl/min for trace elements, organic carbon sources, or Balling protocols.
  • Systems requiring automatic water changes using two pumps and a program configured and monitored by the aquarist.
  • Controlled supply of reactors or other compatible circuits requiring continuous flow within the manufacturer's stated limits.

The choice between the standalone configuration and the Four Pack is mainly a matter of system layout rather than a change in pumping principle. A standalone unit suits one liquid path or an installation that may be expanded gradually. The Four Pack groups several independent liquid paths on the Base Station, making power distribution and physical organization more compact while leaving each pump separately configured. In both cases, the aquarist still decides what liquid is used, where it is discharged, and which program is appropriate.

How It Works (Planetary Gear Stepper Motor, Laboratory-Grade Tubing & Three Mobius Modes)

The electromechanical and software architecture of the EcoTech Versa:

  • Stepper Motor with Epicyclic Planetary Gearbox:

The drive configuration is designed for precision and durability. The stated flow starts at 6 µl/min, reaches 200 ml/min in continuous operation and 300 ml/min for volumetric delivery.

  • Peristaltic Head on Sealed Bearings:

The head compresses laboratory-grade tubing, keeping the dosed liquid separate from the drive mechanism.

  • Triple Programmable Operational Modes:
  • Auto Mode: Delivers a programmed total volume split across a chosen number of doses during the day.
  • Continuous Mode: Maintains a constant flow when the pump is managed by a compatible external control system.
  • Manual Mode: Runs the pump on demand for priming, purging or other direct operations.
  • Modular Base Station with Centralized Power and Dedicated Fusing:

The Versa Base Station accommodates up to 4 pumps, combines their power supply, and provides tactile indexing buttons.

The operating modes address different workflows. Auto mode is suited to a planned amount that Mobius divides according to the schedule chosen by the user. Manual mode is useful while filling or checking a line because operation remains directly initiated by the user. Continuous mode is intended for a compatible external control arrangement; selecting the mode alone is not a substitute for that control. Calibration links the software command to the real combination of pump, tubing and liquid, so a saved setting should not be treated as universal for every installation.

Compatibility and Placement

  • Tubing Connectors: A female PTC connector and a hose-barb adapter are included; EcoTech also offers dedicated polyurethane tubing and push-to-connect fittings.
  • Mobius Ecosystem: Versa is programmed in the Mobius app; the presence of other devices does not replace the pump's separate configuration.

Compatibility has two separate aspects. Mobius provides the programming interface, while the supplied adapters and the optional tubing system define the physical connection. Neither aspect establishes that every liquid is suitable for the same tubing or schedule. The user should confirm material suitability, keep each fluid path identifiable, and route the inlet and outlet without pinching the tubing. For multiple pumps, labeling the reservoirs and discharge lines makes later calibration and maintenance less ambiguous.

Installation

  • Head Mounting: Dock Versa units onto the Base Station or secure standalone units to the cabinet wall with the screw mounting bracket.

Plan the installation before attaching the pump. The unit should remain accessible for head service and for observing the tubing during priming, while the line path should avoid sharp bends and accidental pulling. With the Four Pack, organize the Base Station and all fluid paths as one service area but verify every pump separately. With a standalone unit, leave enough access around the mounting bracket to remove the pump without disturbing the reservoir or discharge line. After connection, trace each line from its source to its destination before starting a program.

Maintenance and calibration

  • Graduated Cylinder Calibration: Run the guided routine in Mobius and compare the dispensed volume with the collected volume, using the actual tubing and liquid.
  • Peristaltic Tube Replacement: Replace the tubing cartridge using the quick-swap Versa Replacement Tube Assembly.

Calibration is a measurement step, not a permanent property of the product. Repeat it when the working liquid, tubing arrangement or tube cartridge changes, because those elements can alter the relationship between commanded and collected volume. During routine inspection, check the cartridge, connectors and line routing for visible wear, loosening or deformation. Maintenance is easier when changes are made one fluid path at a time and the corresponding Mobius configuration is confirmed before returning that pump to its schedule. The approved sources do not establish a universal fixed replacement interval, so inspection and the manufacturer’s replacement procedure take priority over an invented calendar.

Pros and Limitations

Advantages.

  • Wide Stated Flow Range: From 6 µl/min up to 200 ml/min continuously and 300 ml/min in volumetric mode.
  • Planetary Transmission: Designed to combine precision and robustness in the intended applications.
  • Single or 4-Pack Configuration: The Base Station combines up to four pumps and their power supply.

Operational Limitations.

  • Speed-Dependent Noise: At higher flow rates the motor may be more noticeable; the manufacturer does not state an acoustic value.

The standalone format keeps the installation focused when only one controlled path is needed, whereas the Four Pack improves organization when several independent paths are planned together. The trade-off is that a larger grouped installation requires clearer labeling and more careful verification of each line. Mobius can execute the configured mode and schedule, but it does not identify the liquid, assess chemical compatibility or validate the discharge point. Reliable operation therefore depends on a correct physical installation, a representative calibration and a program reviewed by the aquarist.

Verified data

Verified data
Official modelVX-1
Dimensions80 × 59.4 × 106.9mm
Power consumption12W
Input range100–240 VAC, 50/60 Hz
Peak inrush current1.3A
Minimum flow6μL/min
Maximum continuous200mL/min
Maximum volumetric300mL/min
Stated accuracy≤ 2%
Included connectorsFemale PTC + barbed adapter
ModesAuto / Continuous / Manual

Sources consulted

Reviewed on 2026-08-31

  1. EcoTech Marine Versa

    EcoTech Marine · Source: official product

  2. Versa quick-start guide

    EcoTech Marine Customer Support · Source: official manual