Configurator

Configure your tank

A first technical estimate for sizing volume, bracing, and glass thickness. Results are indicative and must be verified before building.

Add it to your bookmarks or share it to find this calculator again.

Design the model

Work on dimensions, safety margin, and bracing from one control desk.

Live calculation
Dimensions and safety

3D preview

Rotate the model to check proportions and bracing as you work.

60 cm × 25 cm × 40 cm60 LSafety factor 3.8

Calculations

Recommendations update with every change to the model.

Max commercial thickness

10 mmRimless
Front/side glass
6 mm
Calculated minimum: 5.74 mm
Bottom glass
10 mm
Calculated minimum: 8.73 mm

Calculates against the full free span of the panels.

Technical detail

Volumes, deflection, spans, and coefficients used for sizing.

Gross volume
60 L
Water volume
60 L
Glass area
0.83 m²
Estimated max deflection
0.33 mm
Front/side thickness
Minimum 5.74 mm · Recommended 6 mm
Bottom thickness
Minimum 8.73 mm · Recommended 10 mm

Front panel

Calculated span
600 mm
Ratio
1.5
Minimum
5.74 mm
α / β
0.042 / 0.26

Side panel

Calculated span
250 mm
Ratio
0.625
Minimum
3.7 mm
α / β
0.00714 / 0.10804

Bottom

Calculated span
600 mm
Ratio
2.4
Minimum
8.73 mm
α / β
0.10914 / 0.60192
Safety note: Non-certified technical estimate. Before building, validate thickness, glass, and bracing with a qualified glazier.
Method: Warren/Stilwell formula based on Alpha/Beta coefficients from Roark's Formulas for Stress and Strain. Roark's Formulas · Aquarium World