Configurator

Configure your tank

A first technical estimate for sizing volume, bracing, and glass thickness. Results are indicative and must be verified before building.

Caricamento 3D…

Calculations

Front/side glass
6 mm
Calculated minimum: 5.74 mm
Bottom glass
10 mm
Calculated minimum: 8.73 mm
Max commercial thickness: 10 mm

Calculates against the full free span of the panels.

Gross volume
60 L
Water volume
60 L
Glass area
0.83 m²
Estimated max deflection
0.33 mm
Front/side thickness
Minimum 5.74 mm · Recommended 6 mm
Bottom thickness
Minimum 8.73 mm · Recommended 10 mm

Front panel

Calculated span
600 mm
Ratio
1.5
Minimum
5.74 mm
α / β
0.042 / 0.26

Side panel

Calculated span
250 mm
Ratio
0.625
Minimum
3.7 mm
α / β
0.00714 / 0.10804

Bottom

Calculated span
600 mm
Ratio
2.4
Minimum
8.73 mm
α / β
0.10914 / 0.60192
Safety note: Non-certified technical estimate. Before building, validate thickness, glass, and bracing with a qualified glazier.
Method: Warren/Stilwell formula based on Alpha/Beta coefficients from Roark's Formulas for Stress and Strain. Roark's Formulas · Aquarium World